Agilent 5975C GC/MS
Refurbished Agilent 5975C GC/MS
When you purchase a refurbished Agilent 5975C GC/MS from Analytical Instrument Management you will be amazed at the amount of detail and testing that goes into our end product
Agilent Technologies 5975C GC/MS
- The 5975C is offered with a diffusion (diff) pump or turbo pump.
Agilent 5975C TAD Series GC/MSD System The Agilent 5975C TAD Series Gas Chromatograph/Mass Selective Detector (GC/MSD) with the Triple-Axis High Energy Diode (HED) Electron Multiplier (EM) Detector provides the flexibility, capabilities, and performance demanded by modern applications in all industries.
The 5975C TAD Series GC/MSD provides high performance and high productivity with features that will improve your analysis



Agilent 5975C Specifications
- Mass Spectrometer
- Mode (standard) EI
- Modes (optional) PCI, NCI, and EI acquisition with CI
- Source
- EI ion source type Noncoated inert EI source
- Sources EI source provided with all systems
- CI source for PCI, NCI, and EI added to CI systems
- Ionization energy 5–241.5 eV
- Ionization current 0–315 μA
- CI gases Dual gas inlet
- Filaments Dual for EI, single for CI
- Transfer line temperature 100–350 °C
- Ion source temperature 150–350 °C
- Quadrupole temperature 106–200 °C
- Mass filter Monolithic hyperbolic quadrupole
- Mass filter protection Entrance lens
- Minimum mass 1.6 u
- Maximum mass 1050 u
- Mass resolution Unit mass adjustable by tune
- Mass axis stability Better than 0.10 u/48 h
- Detector Triple-Axis Detector with long life EM
- Dynamic range (electronic) 10e6
- Scan rate (electronic) Up to 12,500 u/s
- Write-to-disk Up to 8,000 u/s
- SIM 60 ions × 100 groups
- Diffusion Pumping system 65 L/s and 71 L/s
- Turbo Pumping system for the or 260 L/s pump with 2.5 m3/hr mechanical
- Maximum recommended 1.5 mL/min (diffusion)
- analytical gas flow, mL/min 2 mL/min (standard turbo)
- 4 mL/min (performance turbo)
- Recommended maximum 3.0 mL/min (diffusion)
- sustained column flow 5.0 mL/min (standard turbo)
- to MS 15.0 mL/min (performance turbo)
Agilent GC Options for 5975C Mass Spec
- Agilent – 6890 Gas Chromatograph
- Agilent – 7890 Gas Chromatograph

Why Choose AIM
Your reconditioned GC/MS system will be thoroughly tested in our state of the art laboratory by AIM service engineers that are also analytical chemists, all of whom have years of hands on analytical lab experience. This allows us to prove that our systems are meeting not only the manufacturer’s specifications but performing at the level in which you need for your specific analysis.
All refurbished GC/MS systems include but are not limited to:
- New Electron Multipliers
- New Filaments
- New Ion Source Repeller
- New Vacuum Hoses
- Rebuilt Rough Pump with fresh oil
- New Seals
- New Inlet seals
- New Liners
- New Septa
- New Custom Built PC Data Systems with new 27″ displays
Warranty and Expert Support
All GC/MS systems come with an AIM warranty ensuring lasting performance for many years to come. Our warranty program reflects our confidence in the quality of our refurbishment process and commitment to your laboratory’s success. Technical support is available from the same experienced team that refurbished your system, ensuring continuity and deep familiarity with your instrument’s configuration and performance characteristics.